| AFUE Rating | : | 81 % |
| AFUE | : | 81% |
| Additional Information | : | Outdoor Fan - HP: 1/6|Outdoor Fan - Number of Speeds: 1|Outdoor Fan - Speed: 830|Outdoor Fan - Type: Propeller|Outdoor Unit: Fan Motor FLA: 0.85|Power Input kW: 4.01/2.21 (High/Low)|Power Supply: 208/230 V/1 Phase/60 Hz|Refrigerant Charge lbs: 7 lbs - 3.2 oz|Refrigerant Type: R-454B|SEER2: 15.2|Sound Rating (dB): 71|Subcooling Temperature: 10 deg F|Temperature Rise (Min-Max) deg F: 30 to 60 |
| Airflow CFM | : | 1580/1160 (High/Low) |
| CFM Rating | : | 1,600 cfm |
| Capacity (BtuH) | : | 38000 (Low) |
| Combustion Fan Drive | : | Direct |
| Combustion Fan Motor HP | : | 1/20 |
| Combustion Fan Power | : | 208/230 V/1 Phase/60 Hz |
| Combustion Fan Speeds | : | 2 |
| Combustion Fan Type | : | Centrifugal |
| Combustion Fan-RPM | : | 3350/2600 |
| Compressor LRA | : | 138 |
| Compressor Power Rating | : | 208/230 V/1 Phase/60 Hz |
| Compressor RLA | : | 18.3 |
| Compressor Type | : | Scroll |
| Cooling Capacity (BtuH) | : | 57000 |
| Cooling Capacity | : | 48,000 BTU |
| Crated Dimensions (H X W X D) | : | 52 x 47 x 62 in |
| Decibel Rating | : | 71 dBA |
| Drill Size Nat Gas (Qty - Drill Size) | : | 3 - #37 |
| EER2 | : | 11.5 |
| Filter Furnished | : | No |
| Filter Type Recommended | : | Throwaway |
| Filter-Face Area sq-ft | : | 5.3 |
| Frequency Rating | : | 60 Hz |
| Fuse Rating | : | 45 A |
| Heating Capacity Stage 1 | : | 72000 |
| Heating Capacity Stage 2 | : | 90000 |
| Heating Capacity | : | 90,000 BTU |
| Indoor Coil-Drain Connection Size | : | 3/4 in NPT |
| Indoor Coil-FPI | : | 15 |
| Indoor Coil-Face Area sq-ft | : | 5 |
| Indoor Coil-Refrigeration Control | : | TXV |
| Indoor Coil-Rows | : | 4 |
| Indoor Coil-Type | : | Plate Fin |
| Indoor Coil: Tube Size (In.) | : | 0.375 |
| Indoor Fan Type | : | ECM |
| Indoor Fan-Dia x W in | : | 11.87 x 10.68 |
| Indoor Fan-Drive | : | Direct |
| Indoor Fan-Number of Speeds | : | Variable |
| Indoor Fan: Motor HP (Standard/Oversized) | : | 3/4 |
| Indoor Unit: Fan Motor FLA | : | 6.8 |
| Indoor Unit: Fan Motor Speed RPM | : | Variable |
| Input BTU Rating | : | 48,000 Btu/hr |
| Line Size - Suction (In) | : | 1/2 |
| MCA | : | 31 |
| Max Fuse | : | 45 A |
| Model | : | 5YCZ5 |
| Number of Stages | : | Two |
| Outdoor Coil-FPI | : | 24 |
| Outdoor Coil-Face Area sq-ft | : | 23.57 |
| Outdoor Coil-Rows | : | 2 |
| Outdoor Coil-Tube Size (In) | : | 3/8 |
| Outdoor Coil-Type | : | Spine Fin |
| Outdoor Coil: Refrigerant Control | : | Expansion Valve |
| Outdoor Fan - CFM | : | 4200 |
| Outdoor Fan - Diameter In | : | 28.2 |
| Outdoor Fan - Drive | : | Direct |
| Phase | : | 1 ph |
| Refrigerant Type | : | R-454B |
| SEER 2 Rating | : | 15.2 |
| Series | : | Priority |
| Tonnage | : | 4.0 ton |
| Voltage Rating | : | 208/230 V |
Trane 5YCZ5048A1090A, Priority, 4T, 15.2 SEER2, 48,000 BTU Cooling, 90,000 BTU Heating, 81% AFUE, R454B, TXV Metering, ECM Motor, Two Stage Gas Furnace / Air Conditioner Package Unit
- The Climatuff® two-stage compressor features internal over temperature and pressure protector, total dipped hermetic motor. Other features include: centrifugal oil pump, and low vibration and noise.
- Indoor Air Fan — Direct-drive, forward-curved, centrifugal wheel in a Composite Vortica® Blower housing.
- The Spine Fin ™ condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is
- protected on all four sides by louvered panels.
- Gas-Fired Heating System — Models shall provide completely assembled, wired and piped gas fired heating systems within unit.
- Forced Combustion Blower — Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility.
- Heat Exchanger — stainless steel tubes. Free floating design.
- Lower global warming potential R-454B refrigerant
- Burners — stainless steel. Multi-port inshot.