White Rodgers Integrated Furnace Controls 50A65-843 Universal HSI Furnace Control, 25 VAC (Input), 120 VAC (Outputs), 80 VAC (Ignitor), 1/4" Quick Connect, Terminal (Thermostat Inputs R,c,w,y,g), Terminal (Humidifier), Terminal (Electronic Air Cleaner), Terminal (Motor/Park), Natural Gas, LP Gas, 1.5 A (Valve, 25 VAC, 0.6 Pf); 6.0 A (Ignitor, Resistive, 120 VAC); 2.2 A / 3.5 A (Inducer, FLA / LRA, 120 VAC); 14.5 A / 25.0 A (Circulator, FLA / LRA, 120 VAC); 1 A (EAC/HUM, 120 VAC), Flush Mount, 30 Seconds (Pre-Purge); 15 Seconds (Post-Purge); 60 Seconds (Interpurge); 20 Seconds (Initial Ignitor Warm-Up); 4 Seconds (Trial For Ignition); 12 Seconds (Valve Sequence Period); 300 Seconds (Lockout); 3600 Seconds (Auto Reset); 5 Seconds (Cool Fan On Delay); 30 Seconds, 45 Seconds (Adjustable, Heat Fan On Delay); 45 Seconds, 90 Seconds (Adjustable, Cool Fan Off Delay); 60 Seconds, 90 Seconds, 120 Seconds, 180 Seconds (Adjustable, Heat Fan Off Delay); ≤2.0 Seconds (Flame Failure Response); ≤0.8 Seconds (Flame Establishing Time) Time Delay, -40-175 °F Temperature Rating
White Rodgers Integrated Furnace Controls 50A65-843 Universal HSI Furnace Control, 25 VAC (Input), 120 VAC (Outputs), 80 VAC (Ignitor), 1/4" Quick Connect, Terminal (Thermostat Inputs R,c,w,y,g), Terminal (Humidifier), Terminal (Electronic Air Cleaner), Terminal (Motor/Park), Natural Gas, LP Gas, 1.5 A (Valve, 25 VAC, 0.6 Pf); 6.0 A (Ignitor, Resistive, 120 VAC); 2.2 A / 3.5 A (Inducer, FLA / LRA, 120 VAC); 14.5 A / 25.0 A (Circulator, FLA / LRA, 120 VAC); 1 A (EAC/HUM, 120 VAC), Flush Mount, 30 Seconds (Pre-Purge); 15 Seconds (Post-Purge); 60 Seconds (Interpurge); 20 Seconds (Initial Ignitor Warm-Up); 4 Seconds (Trial For Ignition); 12 Seconds (Valve Sequence Period); 300 Seconds (Lockout); 3600 Seconds (Auto Reset); 5 Seconds (Cool Fan On Delay); 30 Seconds, 45 Seconds (Adjustable, Heat Fan On Delay); 45 Seconds, 90 Seconds (Adjustable, Cool Fan Off Delay); 60 Seconds, 90 Seconds, 120 Seconds, 180 Seconds (Adjustable, Heat Fan Off Delay); ≤2.0 Seconds (Flame Failure Response); ≤0.8 Seconds (Flame Establishing Time) Time Delay, -40-175 °F Temperature Rating
| Amperage Rating | : | 0.45 A (Max Input, 25 VAC) |
| Connection Size | : | 1/4" Quick-Connect, 3/16" (Terminal For Lennox) |
| Connection Type | : | 1/4" Quick Connect, Terminal (Thermostat Inputs R,C,W,Y,G), Terminal (Humidifier), Terminal (Electronic Air Cleaner), Terminal (Motor/Park) |
| Contact Rating | : | 1.5 A (Valve, 25 VAC, 0.6 pf); 6.0 A (Ignitor, Resistive, 120 VAC); 2.2 A / 3.5 A (Inducer, FLA / LRA, 120 VAC); 14.5 A / 25.0 A (Circulator, FLA / LRA, 120 VAC); 1 A (EAC/HUM, 120 VAC) |
| Dimensions | : | 4 in H x 30 in W x 1-1/2 in D |
| Frequency Rating | : | 50 Hz, 60 Hz |
| Gas Type | : | Natural Gas, LP Gas |
| Humidity Rating | : | 5 to 93 % |
| Mounting Type | : | Flush Mount |
| Pre Purge Time | : | 30 seconds |
| Series | : | Integrated Furnace Controls |
| Suitable For Use With | : | Gas Fired Forced Air Furnaces (with Integrated Furnace Control Module and Nitride Ignitor); Replaces: OEM, Trane, York, ICP, Amana Models |
| Temperature Rating | : | -40-175 °F |
| Time Delay | : | 30 seconds (Pre-Purge); 15 seconds (Post-Purge); 60 seconds (Interpurge); 20 seconds (Initial Ignitor Warm-Up); 4 seconds (Trial For Ignition); 12 seconds (Valve Sequence Period); 300 seconds (Lockout); 3600 seconds (Auto Reset); 5 seconds (Cool Fan On Delay); 30 seconds, 45 seconds (Adjustable, Heat Fan On Delay); 45 seconds, 90 seconds (Adjustable, Cool Fan Off Delay); 60 seconds, 90 seconds, 120 seconds, 180 seconds (Adjustable, Heat Fan Off Delay); 2.0 seconds (Flame Failure Response); 0.8 seconds (Flame Establishing Time) |
| Voltage Rating | : | 25 VAC (Input), 120 VAC (Outputs), 80 VAC (Ignitor) |
The 50A65-843 Universal Nitride Integrated Ignition module is an automatic ignition control that employs a microprocessor that continually monitors, analyzes, and controls the proper operation of the gas burner, inducer, and fan. The 50A65-843 is unique because it incorporates a patented adaptive algorithm routine that uses an 80V nitride ignitor to ensure the most effective ignitor temperature, increasing the life expectancy of the ignitor.This one module will replace all of the 50A65-XXX integrated ignition nitride modules that have been manufactured by White-Rodgers. The Universal Module has an extensive cross reference for replacement and includes additional jumper wires, additional wiring harness, a jumper for Trane applications and a 3/16†terminal for Lennox (only). The module also has terminals for powering a humidifier and an air cleaner.
White Rodgers Universal HSI Furnace Control, Model: Integrated Furnace Controls, 25 VAC (Input), 120 VAC (Outputs), 80 VAC (Ignitor), 1/4" Quick Connect, Terminal (Thermostat Inputs R,c,w,y,g), Terminal (Humidifier), Terminal (Electronic Air Cleaner), Terminal (Motor/Park), Natural Gas, LP Gas, 1.5 A (Valve, 25 VAC, 0.6 Pf); 6.0 A (Ignitor, Resistive, 120 VAC); 2.2 A / 3.5 A (Inducer, FLA / LRA, 120 VAC); 14.5 A / 25.0 A (Circulator, FLA / LRA, 120 VAC); 1 A (EAC/HUM, 120 VAC), Flush Mount, 30 Seconds (Pre-Purge); 15 Seconds (Post-Purge); 60 Seconds (Interpurge); 20 Seconds (Initial Ignitor Warm-Up); 4 Seconds (Trial For Ignition); 12 Seconds (Valve Sequence Period); 300 Seconds (Lockout); 3600 Seconds (Auto Reset); 5 Seconds (Cool Fan On Delay); 30 Seconds, 45 Seconds (Adjustable, Heat Fan On Delay); 45 Seconds, 90 Seconds (Adjustable, Cool Fan Off Delay); 60 Seconds, 90 Seconds, 120 Seconds, 180 Seconds (Adjustable, Heat Fan Off Delay); ≤2.0 Seconds (Flame Failure Response); ≤0.8 Seconds (Flame Establishing Time) Time Delay, -40-175 °F Temperature Rating, 1/4" Quick-Connect, 3/16" (Terminal For Lennox) Connection Size, 0.45 A (Max Input, 25 VAC), 50 Hz, 60 Hz
- Universal design replaces many White-Rodgers and OEM 80V HSI controls for PSC motors.
- Microprocessor control with adaptive algorithm optimizes 80V nitride ignitor temperature and lifespan.
- On-board diagnostic LED flashes fault codes for easier troubleshooting.
- Provides 120V connections for powering humidifiers and electronic air cleaners (up to 1A).
- Features adjustable heat/cool fan on/off delays for customized comfort.
- Includes necessary jumpers and harnesses for broad compatibility and flexible installation.
- CSA Certified for safety and reliability.