AFUE Rating % | : | 97 |
Ampacity | : | 13.43 |
Blower (Dia x W) (In) | : | 11 x 10 |
Blower Drive | : | Direct |
Blower FLA | : | 10 |
Blower Fan Motor HP | : | 1 |
Blower Fan Power | : | 120 V/1 Phase/60 Hz |
Blower Fan RPM | : | Variable |
Burner Type | : | Inshot |
Capacity (BtuH) | : | Stage1 = 77050 (ICS); Stage2 = 116250 (ICS) |
Combustion Fan Drive | : | Direct |
Combustion Fan FLA | : | 0.77 |
Combustion Fan Inducer Orifice | : | 1.19 |
Combustion Fan Motor HP | : | 1/50 |
Combustion Fan Power | : | 33/110 V/3Phase/60/180 Hz |
Combustion Fan Speeds | : | Variable |
Combustion Fan Type | : | Variable |
Combustion Fan-RPM | : | 5000 |
Configuration | : | Upflow, Horizontal |
Crated Dimensions (H X W X D) | : | 35-1/2 x 26-1/2 x 30-7/8 in |
Drill Size LP Gas (Qty - Drill Size) | : | 6 - 56 |
Drill Size Nat Gas (Qty - Drill Size) | : | 6 - 45 |
Energy Star Compliant | : | Yes |
Filter Furnished | : | No |
Filter Hi Vel. (No.-Size-Thk.) | : | 1 - 24 x 25 - 1 |
Filter Type Recommended | : | High Velocity |
Gas Valve Type | : | Redundant - 2-Stage |
Heat Exchanger Gauge (Fired) | : | 20 |
Heat Exchanger Type - Fired | : | 409 Stainless Steel |
Heat Exchanger Type - Unfired | : | 29-4C Stainless Steel |
Inlet Size (In) | : | 3 in Round |
Input BTUH Stage 1 (BTU-HR) | : | 78000 |
Input BTUH Stage 2 (BTU-HR) | : | 120,000 |
Line Size - Suction (In) | : | 1/2 |
MOCP | : | 15 |
Model Number | : | S9V2 |
Number of Blower Speed | : | Variable |
Number of Blower Wheels Used | : | 1 |
Number of Burners | : | 6 |
Pilot Safety Device | : | SiNi Igniter |
Power Supply | : | 120 V/1 Phase/60 Hz |
Return Air Temp. (Min. - Max.) deg F | : | 45 - 80 |
Temperature Rise (Min-Max) deg F | : | Stage1 = 35 to 65; Stage2 = 40 to 70 |
Uncrated Dimensions (HxWxD) | : | 34 x 24-1/2 x 28-3/4 in |
Vent Size | : | 3 in Round |