| AMP | : | 25 A (Max Fuse) |
| BTU Cooling Rating | : | 30,000 Btu/hr |
| Blower Diameter | : | 23 in |
| Blower Motor Type | : | PSC |
| Capacity (Kg) | : | 2540.12 |
| Charging Specification Subcooling | : | 12 deg F |
| Compressor Insulation/Sound Blanket | : | No |
| Compressor LRA | : | 71 |
| Compressor RLA | : | 10.4 |
| Compressor Stages | : | Single Stage |
| Compressor Sump Heater Factory Installed | : | No |
| Compressor Type | : | Scroll |
| EER2 | : | 11.7 |
| Elec Hertz | : | 60 Hz |
| Elec Phases | : | 1 ph |
| Elec Volts | : | 208/230 V |
| Factory Installed Start Components | : | BAYKSKT263 |
| Fin Type | : | Spine Fin |
| Full Load Amperage (FLA) | : | 0.64 |
| HSPF2 Range | : | 8.1 |
| HSPF2 | : | 7.5-8.1 |
| Line Size - Liquid (in) | : | 5/16 |
| Line Size - Suction (In) | : | 3/4 |
| MCA | : | 16 |
| Max Fuse Size | : | 25 amps |
| Max Fuse | : | 25 A |
| Motor Speed | : | 850 rpm |
| Noise Level | : | 71 dba |
| Number of Fans | : | 1 |
| Number of Stages | : | Single |
| Phase | : | 1.0 ph |
| Power Supply | : | 208/230 V/1 Phase/60 Hz |
| Product Family Series | : | 15 Single-Stage Heat Pump |
| Refrigerant Control | : | TXV |
| Refrigerant Type | : | R-454B |
| Rows - Fins per Inch | : | 1 - 24 |
| SEER Rating | : | 15.2 |
| SEER2 Range | : | 8.1 |
| SEER | : | 15 |
| Series | : | 14 Single Stage Heat Pump |
| Sound Rating (dB) | : | 71 dBA |
| Specifications - UL Listed | : | Yes |
| Stages | : | 1 |
| Tonnage | : | 2.5 Ton |
| Tube Size (In) | : | 3/8 |
| Type | : | Split System Heat Pump |
| Volts | : | 208/230 V |
Trane 5TWR5030A1000A, 15 Single-Stage Heat Pump, 2.5T, 15.2 SEER2, 30,000 BTU, 208/230V, R454B, 8.1 HSPF
- 15 SEER2 heat pumps meet 2025 Low Global Warming Potential (Low GWP) regulatory criteria using R-454B refrigerant
- New TXV and refrigeration designs that are optimized for maximum performance using the new refrigerant
- Compatibility with existing accessories and kits
- Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test.
- The compressor features internal over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise.
- The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels
- Refrigeration system controls include condenser fan, compressor contactor and low and high pressure switches. A factory supplied, field installed liquid line drier is standard.