AMP | : | 25 A (Max Fuse) |
BTU Cooling Rating | : | 30,000 Btu/hr |
Blower Diameter | : | 23 in |
Blower Motor Type | : | PSC |
Capacity (Kg) | : | 2540.12 |
Charging Specification Subcooling | : | 12 deg F |
Compressor Insulation/Sound Blanket | : | No |
Compressor LRA | : | 71 |
Compressor RLA | : | 10.4 |
Compressor Stages | : | Single Stage |
Compressor Sump Heater Factory Installed | : | No |
Compressor Type | : | Scroll |
EER2 | : | 11.7 |
Elec Hertz | : | 60 Hz |
Elec Phases | : | 1 ph |
Elec Volts | : | 208/230 V |
Factory Installed Start Components | : | BAYKSKT263 |
Fin Type | : | Spine Fin |
Full Load Amperage (FLA) | : | 0.64 |
HSPF2 Range | : | 8.1 |
HSPF2 | : | 7.5-8.1 |
Line Size - Liquid (in) | : | 5/16 |
Line Size - Suction (In) | : | 3/4 |
MCA | : | 16 |
Max Fuse Size | : | 25 amps |
Max Fuse | : | 25 A |
Motor Speed | : | 850 rpm |
Noise Level | : | 71 dba |
Number of Fans | : | 1 |
Number of Stages | : | Single |
Phase | : | 1.0 ph |
Power Supply | : | 208/230 V/1 Phase/60 Hz |
Product Family Series | : | 15 Single-Stage Heat Pump |
Refrigerant Control | : | TXV |
Refrigerant Type | : | R-454B |
Rows - Fins per Inch | : | 1 - 24 |
SEER Rating | : | 15.2 |
SEER2 Range | : | 8.1 |
SEER | : | 15 |
Series | : | 14 Single Stage Heat Pump |
Sound Rating (dB) | : | 71 dBA |
Specifications - UL Listed | : | Yes |
Stages | : | 1 |
Tonnage | : | 2.5 Ton |
Tube Size (In) | : | 3/8 |
Type | : | Split System Heat Pump |
Volts | : | 208/230 V |
Trane 5TWR5030A1000A, 15 Single-Stage Heat Pump, 2.5T, 15.2 SEER2, 30,000 BTU, 208/230V, R454B, 8.1 HSPF
- 15 SEER2 heat pumps meet 2025 Low Global Warming Potential (Low GWP) regulatory criteria using R-454B refrigerant
- New TXV and refrigeration designs that are optimized for maximum performance using the new refrigerant
- Compatibility with existing accessories and kits
- Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test.
- The compressor features internal over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise.
- The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels
- Refrigeration system controls include condenser fan, compressor contactor and low and high pressure switches. A factory supplied, field installed liquid line drier is standard.